06 — Host-Level GPU Utilization

The fleet view (doc 05) tells you which teams waste GPUs. The host view tells you why a specific GPU on a specific node is slow right now. Different audiences, different metrics.

This is the SRE drilldown level: when an inference service breaches p99 or a training rank lags, you arrive on the host dashboard for that node and these are the metrics you read in order.


1. The 8 Per-Host Metrics That Diagnose 90% of Slowness

When a node-scoped GPU issue is reported, walk this list top to bottom. Each panel either resolves the case or escalates to the next.

# Signal Tells you
1 DCGM_FI_DEV_CLOCK_THROTTLE_REASONS Is the GPU actively being clocked down?
2 DCGM_FI_DEV_GPU_TEMP, DCGM_FI_DEV_MEMORY_TEMP Thermal — die vs HBM separately
3 DCGM_FI_DEV_POWER_USAGE vs TDP Power-limited?
4 DCGM_FI_DEV_PCIE_LINK_GEN, DCGM_FI_DEV_PCIE_LINK_WIDTH PCIe link degraded?
5 DCGM_FI_PROF_PCIE_RX_BYTES, _TX_BYTES PCIe saturated?
6 NVLink replay/recovery/CRC error rates NVLink degraded?
7 NUMA affinity (CPU socket vs GPU) Wrong NUMA placement?
8 Pinned host memory, IOMMU pressure Host bottleneck?

The order is deliberate — fast-to-check, fast-to-resolve first. Only get to NUMA after the obvious thermal/power/link issues are ruled out.


2. Per-GPU, Per-Node Metric Hygiene

A standard HGX node has 8 GPUs. You want all 8 individually visible:

# Per-GPU temperature on a single node
DCGM_FI_DEV_GPU_TEMP{Hostname="gpu-014"}

Returns 8 series, one per gpu label (0..7). The L3 (host) dashboard is grids of 8 panels, each with all 8 lines plus a max-line for "worst GPU on this node."

Cardinality budget: 8 GPUs × 30 metrics × 1 node = 240 series. Times nodes for the cluster-wide view. Stays comfortable up to 1k nodes (240k series), which is well within Prometheus single-replica limits.


3. PCIe — The Most-Missed Bottleneck

PCIe Gen4 x16 = 32 GB/s theoretical per direction, ~28 GB/s practical. PCIe Gen5 x16 = 64 GB/s theoretical. H100 sits on PCIe Gen5; H200/B200 also Gen5.

Two failure modes you must monitor:

Sometimes a link trains down to Gen3 or x8 due to a marginal connector or thermal event. The GPU is fine, but bandwidth is permanently halved until reboot.

# Alert: PCIe link below expected
DCGM_FI_DEV_PCIE_LINK_GEN < 5  # or < 4 for older HW
DCGM_FI_DEV_PCIE_LINK_WIDTH < 16

This is one of the cheapest, most-impactful alerts you can write. We've seen multi-percent training throughput regressions from a single Gen3 GPU in an 8-GPU node (the slow GPU drags AllReduce).

3.2 PCIe saturation

When data-loader or H2D copies max out PCIe, GPU starves:

# PCIe link utilization (Gen5 x16 = 64 GB/s peak)
rate(DCGM_FI_PROF_PCIE_RX_BYTES[1m]) / (64 * 1024^3)
rate(DCGM_FI_PROF_PCIE_TX_BYTES[1m]) / (64 * 1024^3)

# Combined when both directions are active
(rate(DCGM_FI_PROF_PCIE_RX_BYTES[1m]) + rate(DCGM_FI_PROF_PCIE_TX_BYTES[1m]))
/ (64 * 1024^3 * 2)  # full-duplex peak

The asymmetric-contention reality (per NVIDIA forums): bidirectional H2D+D2H reduces each direction's bandwidth by ~25–55% even on Gen4. A workload that's I/O-bound during training data loading often sees this exact pattern. Don't trust the per-direction max; watch the bidirectional rate.

3.3 The signature

If SM_ACTIVE is low and PCIE_RX_BYTES is at 80%+ of peak, you're PCIe-starved. The fix is workload-side (larger batches to amortize H2D, prefetch, GPUDirect Storage if available). The metric just tells you it's the bottleneck.


NVLink fabric on an HGX H100 baseboard: every pair of GPUs connected via 18 NVLink-4 links bonded (NV18 in nvidia-smi topo -m), giving ~900 GB/s per direction per pair.

4.1 Bandwidth utilization

# Per-link NVLink RX bandwidth utilization
sum by (Hostname, gpu, nvlink) (
  rate(DCGM_FI_PROF_NVLINK_RX_BYTES[1m])
) / (25 * 1024^3)  # NVLink-4 = 25 GB/s/link

Healthy AllReduce during distributed training: 70–95% utilization on every link, all GPUs symmetric. Asymmetric utilization (one link at 90%, others at 30%) means NCCL didn't pick a balanced ring/tree — usually a topology mismatch.

4.2 Error counters — leading indicator of degradation

These are the most underrated metrics in the stack:

Counter Meaning
DCGM_FI_DEV_NVLINK_REPLAY_ERROR_COUNT_TOTAL Transient packet replay (link recovered)
DCGM_FI_DEV_NVLINK_RECOVERY_ERROR_COUNT_TOTAL Link reset event
DCGM_FI_DEV_NVLINK_CRC_FLIT_ERROR_COUNT_TOTAL Per-flit CRC error (data corruption)
DCGM_FI_DEV_NVLINK_CRC_DATA_ERROR_COUNT_TOTAL Data CRC error
# Recovery error rate per link
rate(DCGM_FI_DEV_NVLINK_RECOVERY_ERROR_COUNT_TOTAL[5m])

A healthy fabric: zero recovery errors for days/weeks. A degraded fabric: increasing rate, often on one specific link first. This is the predictive signal — degraded links cause AllReduce slowdowns hours/days before they fail.

Rule of thumb: > 1 recovery/hour on a single link → ticket; > 10/hour → page; > 100/hour → that link is dying.

The "fabric heatmap" — a matrix of all GPU pairs on a node × bandwidth or error rate. Reveals fabric-wide vs link-specific issues:

# Per-pair bandwidth (synthetic, requires topology metadata)
nvlink_pair_bandwidth_bytes_per_sec{
  Hostname="gpu-014",
  src_gpu="0",
  dst_gpu="1"
}

Doc 09 has the dashboard JSON.


5. NUMA Affinity Correctness

On a dual-socket HGX node, GPUs split between NUMA nodes:

Socket 0 (NUMA 0): CPUs 0-47    GPUs 0-3
Socket 1 (NUMA 1): CPUs 48-95   GPUs 4-7

A process on CPU 5 talking to GPU 6 traverses the QPI/UPI link → significant latency, halved bandwidth. NCCL pinning fixes this; misconfigured pods don't.

5.1 What to check

Per pod:

# Inside the pod
cat /proc/self/status | grep ^Cpus_allowed_list
nvidia-smi topo -m

Cross-reference: which CPUs is the process allowed on, and which NUMA node owns the GPU? If they don't match, you have a misconfiguration.

5.2 Synthetic metric

A small init container or sidecar can emit:

# 1 if mismatch, 0 if correct
gpu_numa_misalignment{
  Hostname="gpu-014",
  pod="train-0",
  gpu="6"
} 1

Then a cluster-wide alert:

sum(gpu_numa_misalignment) > 0

Most clusters have nonzero misalignment. The fix is the kubelet's Topology Manager (policy: single-numa-node) or pod-level topologyManagerPolicy plus correct CPU manager static policy.

5.3 The cost of getting it wrong

For LLM inference workloads with heavy host↔device traffic (KV cache resharding, embedding lookups), NUMA mis-pinning costs 10–30% of throughput. For pure-compute training that lives entirely in HBM, the cost is closer to 1–5%. Either way, free performance for fixing config.


6. Network — InfiniBand / RoCE Fabric

The third interconnect tier (after PCIe within node, NVLink between GPUs on a node): network between nodes for multi-node training.

NCCL prefers RDMA over TCP for collective ops. The standard fabric on production GPU clusters is InfiniBand (NDR 400 Gb/s) or RoCEv2 over Ethernet (Spectrum-X). NCCL drives traffic at near-line-rate during AllReduce.

6.1 Metrics to scrape

From node-exporter with --collector.infiniband:

Metric Use
node_infiniband_port_data_received_bytes_total RX bytes per port
node_infiniband_port_data_transmitted_bytes_total TX bytes per port
node_infiniband_port_excessive_buffer_overrun_errors_total Buffer overruns
node_infiniband_port_link_downed_total Link bounces
node_infiniband_port_local_link_integrity_errors_total Local errors
node_infiniband_port_packet_seq_err_total Packet sequence errors
node_infiniband_port_symbol_error_total Symbol errors

Healthy IB fabric during AllReduce should show:

  • TX ≈ RX (collective is symmetric)
  • Each port near link rate (e.g., 50 GB/s for NDR x4)
  • Zero or near-zero error counters

6.2 Detection: network-starved collectives

A telling signature of network bottleneck:

# AllReduce is slow AND IB is saturated AND NVLink is idle
DCGM_FI_PROF_NVLINK_TX_BYTES < 10e9   # NVLink mostly idle
  and on(Hostname)
rate(node_infiniband_port_data_transmitted_bytes_total[1m]) > 40 * 1024^3  # IB saturated

Translation: the cross-node AllReduce is bottlenecked on network, not compute. Mitigations are sharding/topology decisions (rail-optimized fabric, hierarchical AllReduce), not hardware.

6.3 Network errors that page

Error Severity
link_downed_total increasing Page — fabric is bouncing
excessive_buffer_overrun Page — congestion control failing
symbol_error rate increasing Ticket — cable/transceiver degrading
packet_seq_err Ticket — usually transient

7. Host Memory and IOMMU

The most-overlooked layer. A misconfigured pinned-memory setup throttles all H2D copies:

7.1 Pinned (page-locked) memory

CUDA cudaMallocHost/PyTorch pin_memory=True allocates host memory the kernel won't page out, enabling DMA without staging. If pinned-memory allocation fails (limit hit, fragmentation), kernels fall back to staged copies → 2–3× slower H2D.

# Host memory pressure
node_memory_MemFree_bytes / node_memory_MemTotal_bytes < 0.05

Plus container-level limits: kube_pod_container_resource_requests{resource="memory"} should leave headroom for pinned allocation.

7.2 Transparent HugePages (THP)

Counterintuitive: THP can hurt GPU workloads because the kernel's defrag interrupts blocking pinned-memory allocation. Production GPU nodes typically run with transparent_hugepage=madvise or =never.

Detection from node-exporter:

node_vmstat_thp_collapse_alloc  # rate of THP collapses
node_vmstat_thp_split_pmd       # PMD splits

High rates correlate with H2D latency spikes.

7.3 IOMMU pass-through vs translation

Default IOMMU mode adds DMA address translation overhead (~5–15% on H2D). For GPU clusters, set iommu=pt (passthrough) on kernel cmdline.

This isn't a real-time metric — it's a config-correctness check via node-exporter node_kernel_cmdline:

# All nodes have iommu=pt set
absent(node_kernel_cmdline{cmdline=~".*iommu=pt.*"})

If the alert fires for any node, the fleet-wide IOMMU policy isn't applied uniformly.


8. Thermal and Power — Per-Host Detail

Doc 07 covers ECC and hardware health alerts comprehensively. The host-view subset:

8.1 Per-GPU power

# Power draw vs TDP per GPU on a node
DCGM_FI_DEV_POWER_USAGE{Hostname="gpu-014"}
/ DCGM_FI_DEV_POWER_DEFAULT_LIMIT  # TDP for this model

H100 SXM TDP: 700W. H200 SXM: 700W. B200: 1000W (configurable). At sustained > 95% of TDP under load, you're power-throttling territory.

8.2 Junction vs memory temperature

GPU "temperature" is multiple sensors. The two that matter:

Sensor Field Throttle threshold
GPU die (junction) DCGM_FI_DEV_GPU_TEMP ~83–87°C depending on model
HBM (memory) DCGM_FI_DEV_MEMORY_TEMP ~95°C HBM3, 85°C HBM3e

HBM is often the real limiter. A GPU showing die temp at 70°C might be HBM-throttling at 95°C. Always plot both.

8.3 Throttle reason decode

The throttle bitfield (DCGM_FI_DEV_CLOCK_THROTTLE_REASONS):

Bit Reason Severity
0x01 GPU idle Informational
0x02 Application clock setting User-configured
0x04 SW power cap Throttled by user-set power cap
0x08 HW slowdown (thermal) Critical — alert
0x10 Sync boost OK
0x20 SW thermal slowdown Warning
0x40 HW thermal slowdown Critical — page
0x80 HW power brake slowdown Critical — page
0x100 Display clock setting N/A on data center GPUs

Decode in PromQL with bitwise ops (Prometheus 2.41+):

# HW thermal slowdown observed
(DCGM_FI_DEV_CLOCK_THROTTLE_REASONS & 0x40) > 0

Or emit pre-decoded fields from your relabel config.


9. Topology-Aware Affinity Scoring

For multi-GPU pods, a quality score for the placement:

score = sum over (gpu_pair_in_pod) of:
  +10 if NV18 (full NVLink)
  +5 if NV6 (partial NVLink)
  -2 if PIX (PCIe switch)
  -10 if SYS (cross-NUMA)

Computed by the topology exporter (doc 03 §4) and emitted as pod_gpu_topology_score. The dashboard panel ranks pods by score; bad placements bubble to the top for re-scheduling.


10. The "Slow GPU on This Node" Runbook

The exact sequence when paged:

1. open L3 host dashboard for this node
2. check throttle reasons panel
   - HW thermal? → check fan curves, ambient, PSU; ticket facilities
   - SW power cap? → check power policy; revert
   - none? → continue
3. check temperature panel
   - HBM > 95°C? → workload too aggressive; throttle batch size or schedule less hot
   - die > 87°C? → cooling issue
4. check PCIe link gen/width
   - downgraded? → reboot the node; if recurs, RMA
5. check NVLink errors
   - rising recovery rate on one link? → drain workload, run nvlink diagnostics
6. check NUMA affinity panel
   - misalignment? → fix kubelet topology manager
7. check IB error counters
   - link bouncing? → escalate to fabric team
8. last: check workload-side metrics (data loader stalls, etc.)

This runbook lives next to the dashboard in Grafana annotations. Doc 10 covers alert routing so the right person sees the right runbook.


11. Acceptance Checklist

You're ready for Phase 3 when:

  • Per-GPU panels render for every node (8 GPUs visible)
  • PCIe link gen/width alert defined and quiet (no Gen3 surprises)
  • NVLink error rate panels show flat-zero baseline
  • NUMA misalignment metric exists (even if it's nonzero today — at least it's measured)
  • InfiniBand or RoCE port metrics scraped from node-exporter
  • Throttle reasons decoded into individual panels
  • HBM temp plotted separately from die temp
  • Host memory pressure correlated to H2D latency in at least one dashboard

12. Forward Pointers

  • Doc 07: ECC, XID, RMA workflow — hardware health alerting end-to-end
  • Doc 09: L3 host dashboard JSON
  • Doc 10: Throttle/thermal alert routing
  • Doc 15: NVLink/IB metrics joined to per-rank training step time