GPU Platform Tasks — the capacity engineering capstone

Do this after device-plugin-tasks.md. It is the endgame of Track B: five projects that together are a miniature of what a frontier-lab capacity or Kubernetes-platform team actually owns — telemetry ingestion, allocation accounting, planning, queueing, and placement.

Read alongside: ../kubernetes/09-kube-scheduler-internals.md, ../kubernetes/10-kubelet-internals.md, ../kubernetes/21-resource-management-and-qos.md, and all of ../gpu-observability/ (start with its tasks.md).

The one idea: allocation is not utilization, and the gap between them is the entire job.

  requested          allocated           utilized
  (pod spec)   ──▶   (scheduler bound)  ──▶  (SM actually busy)
      8 GPUs             8 GPUs                 0.9 GPUs

  ▲ capacity planning        ▲ scheduling         ▲ observability
    lives here                 lives here            lives here

  Stranding = allocated − utilized.  At fleet scale it is the largest
  single line item anyone can move, and nobody can see it by default.

Every project below exists to measure, expose, or close some part of that gap.


Level 0 — A fleet you can break, without buying GPUs

You do not need real accelerators for projects 1–4. You need nodes that claim to have them.

  1. Fake GPU nodes. Extended resources are advertised through the node status subresource, so you can invent them:
kind create cluster --name gpulab
kubectl proxy &
curl --header "Content-Type: application/json-patch+json" \
  --request PATCH \
  --data '[{"op":"add","path":"/status/capacity/nvidia.com~1gpu","value":"8"}]' \
  http://localhost:8001/api/v1/nodes/gpulab-worker/status

nvidia.com/gpu is now schedulable. Pods requesting it will bind. Nothing runs on a GPU, which is fine — the scheduler, the accounting and the queueing are all real.

  1. A fleet, not a node. Install kwok and stand up 50–200 fake nodes across several invented "regions", "providers" and accelerator types (nvidia.com/gpu, nvidia.com/mig-1g.10gb, google.com/tpu). Heterogeneity is the point — homogeneous fleets hide every interesting problem.

  2. Synthetic DCGM. Write an exporter that emits real DCGM metric names with plausible fake values, per fake GPU. Field names and IDs are in ../gpu-observability/appendix-b-field-ids.md. At minimum:

Metric Meaning
DCGM_FI_DEV_GPU_UTIL fraction of time ≥1 kernel was resident — not occupancy
DCGM_FI_PROF_SM_ACTIVE fraction of time ≥1 warp was active on an SM, averaged over SMs
DCGM_FI_PROF_SM_OCCUPANCY resident warps ÷ max warps
DCGM_FI_PROF_PIPE_TENSOR_ACTIVE tensor-core pipe utilization
DCGM_FI_DEV_FB_USED / _FREE framebuffer memory
DCGM_FI_DEV_POWER_USAGE watts — the honest utilization proxy
DCGM_FI_DEV_XID_ERRORS hardware faults

Give your generator distinct workload shapes: a training job (high SM_ACTIVE, high power, steady), an inference server (bursty, low occupancy, high GPU_UTIL), an idle-but-allocated notebook (GPU_UTIL near zero, memory held). Those three shapes are what the rest of the projects have to tell apart.

  1. Real hardware, once. Rent one GPU for a few hours (Lambda, RunPod, Vast.ai) at the end of project 1 and validate that your synthetic metrics match reality in name, unit and cardinality. A day of real hardware is worth a month of assumptions, and it's the difference between "I simulated this" and "I verified it against a real device."

Project 1 — DCGM → Prometheus

Build: the telemetry substrate everything else reads from.

Levels

  1. Deploy dcgm-exporter as a DaemonSet (or your synthetic exporter on the fake fleet). Scrape it with Prometheus. Confirm the metric names against ../gpu-observability/appendix-b-field-ids.md.
  2. Join GPU metrics to Kubernetes identity. Raw DCGM tells you GPU 3 on node 7 is busy. It does not tell you whose job that is. Attach pod, namespace, and team labels — via the exporter's kubernetes-mapping or your own relabeling from the kubelet pod-resources API. This join is the single most valuable thing in the project; without it there is no attribution and therefore no capacity engineering.
  3. Design the metric schema deliberately. Which labels are worth their cardinality? Compute the series count: GPUs × metrics × label combinations. Read ../gpu-observability/08-prometheus-metrics-design-and-cardinality.md and ../sre-observability/18-cardinality-and-cost.md before you pick labels, not after.
  4. Recording rules for the aggregates you'll reuse: per-node, per-namespace, per-team, per-accelerator-type utilization.
  5. Break it: kill the exporter mid-scrape, restart a node, delete a pod mid-job. Which metrics go stale versus disappear? Staleness that reads as zero utilization will silently corrupt every downstream number.

Acceptance

  • Any GPU-second is attributable to a pod, namespace and team
  • You can state your total series count and defend each label
  • A written note on what happens to each metric when the exporter dies

Read: ../gpu-observability/02-dcgm-exporter-deep-dive.md, 03-k8s-gpu-cluster-observability.md, 08-prometheus-metrics-design-and-cardinality.md.


Project 2 — GPU Capacity & Utilization Dashboard

Build: the allocation-versus-utilization gap, made visible.

Levels

  1. Write a controller (client-go, per controller-tasks.md) that maintains allocation state: for every node, GPUs capacity / allocatable / requested / bound. This comes from the API server, not from DCGM — they are different sources of truth and conflating them is the classic error.
  2. Join allocation against utilization from project 1. Produce, per namespace and per team: allocated GPU-hours, utilized GPU-hours, and stranded GPU-hours (the difference).
  3. Define utilized precisely and defend it. Is a GPU at GPU_UTIL=100%, SM_OCCUPANCY=4% utilized? This is the DCGM semantics trap — the same fleet reads as 90% or 5% utilized depending on which metric you trust. Pick a definition, write down why, and expose both.
  4. Grafana dashboards for three audiences, because the same data must answer three questions:
Audience Question Panel
Researcher "Is my job using the GPU I asked for?" Per-job occupancy over time
Platform lead "Where is capacity stranded?" Stranding heatmap by team × accelerator
Finance "What did that cost?" GPU-hours × rate, by team, by month
  1. Add a per-config baseline: what does "good" occupancy look like for this workload shape? A 40% number is excellent for one shape and terrible for another, and a dashboard without baselines just generates arguments.

Acceptance

  • Stranded GPU-hours per team, computed and defensible
  • Both utilization definitions exposed, with a written rationale for the headline one
  • Three dashboards, each answering exactly one question

Read: ../gpu-observability/05-gpu-allocation-and-utilization-efficiency.md, 06-host-level-gpu-utilization.md, 09-grafana-dashboards.md, 13-multi-tenant-gpu-observability.md.


Project 3 — Kubernetes GPU Capacity Planner

Build: a CRD-driven planning and allocation surface. This is the closest project to the Anthropic Capacity Engineering job description.

Levels

  1. Design the API before writing code. Sketch a GPUAllocation (or CapacityBudget) CRD:
spec:
  team: research-training
  accelerator: nvidia.com/gpu
  guaranteed: 64        # reserved, always available
  burst: 128            # may borrow from the shared pool
  region: us-central1
status:
  allocated: 64
  utilized: 41
  stranded: 23
  borrowedFrom: [inference-pool]

Spend real time on this. operator-tasks.md covers the mechanics; the hard part is the schema, and schema contracts are named explicitly in the job description. 2. Build the operator with controller-runtime. Reconcile: read allocations, read live utilization, compute status, expose it. 3. Enforcement. A budget nobody enforces is a spreadsheet. Add a validating admission webhook (see ../kubernetes/06-admission-control-deep-dive.md) that rejects pods exceeding a team's guaranteed+burst. Then decide what happens to a team that is under-utilizing — reclaim, warn, or nothing — and defend the choice. 4. Rightsizing recommendations. For each workload, compare requested GPUs against p50/p95 observed occupancy and emit a recommendation. Handle the obvious objection: a job that needs 8 GPUs for ten minutes of a two-hour run still needs 8 GPUs. 5. Cost attribution. Attach a rate per accelerator type per region. Produce team-level spend. Then make it multi-provider: two invented providers with different billing models (one on-demand per-second, one with committed-use discounts and reservations). Normalizing these is explicitly a preferred qualification, and it is much harder than it sounds. 6. Forecasting. Given 90 days of allocation history plus a growth signal, project demand and produce a supply plan. Then answer the real question: is the growth causal or merely correlated with a business driver?

Acceptance

  • A CRD you would defend in a design review, with documented schema contracts
  • Enforcement that actually blocks something
  • Team-level cost, normalized across two dissimilar billing models
  • A 90-day forecast with stated assumptions and error bars

Read: ../gpu-observability/12-capacity-planning-and-cost-optimization.md, 17-telemetry-lakehouse-and-sql-analytics.md, ../sre-observability/31-finops-for-observability.md.


Project 4 — GPU Job Queue

Build: admission and queueing for scarce accelerators. Default Kubernetes has no queue — unschedulable pods simply sit Pending, which is not a policy.

Levels

  1. Reproduce the failure first. Submit 20 jobs each requesting 8 GPUs to a 16-GPU fleet. Observe: no ordering, no fairness, no visibility into position. Write down what's wrong.
  2. Gang scheduling. A distributed training job needs all 8 pods or none — 7 running pods holding GPUs while waiting for the 8th is deadlock, and two such jobs deadlock each other permanently. Implement all-or-nothing admission using a Permit plugin with waiting pods, or a job-level workload abstraction that only admits when the whole gang fits.
  3. Queue policy. Priority classes, per-team fairness, ageing so low-priority work isn't starved forever, and backfill so a small job can use a hole while a large one waits. Each is a distinct mechanism; implement them separately.
  4. Preemption and borrowing. A team may borrow idle GPUs from the shared pool, but must surrender them when the owner returns. Decide the eviction contract: grace period, checkpoint signal, or hard kill — and what that means for a 12-hour training run.
  5. Compare against Kueue: ClusterQueue, LocalQueue, ResourceFlavor, Workload, cohorts and borrowing. Read its source. Then write up where your design differs and why. Being able to critique Kueue's model is a strong interview signal; Kueue is named in the Anthropic Kubernetes Platform posting.

Acceptance

  • Gang admission with a demonstrated deadlock-free property
  • Queue position and estimated wait, visible to the submitter
  • Preemption that respects a documented eviction contract
  • A written comparison against Kueue

Read: ../kubernetes/09-kube-scheduler-internals.md (queueing and preemption), ../gpu-observability/04-batch-vs-stateless-workloads.md.


Project 5 — Build Your Own Kubernetes GPU Scheduler

Build: a scheduler-framework plugin that places GPU work better than the default. The hardest project here, and the one that maps to the $405–485k Kubernetes Platform role.

Levels

  1. Learn the extension points cold — you will use six of them:
Point Your use
QueueSort Ordering by priority and age
PreFilter Compute the gang's total demand once
Filter Reject nodes lacking the right accelerator or topology
Score Bin-packing, topology affinity, fragmentation avoidance
Reserve / Permit Gang admission and rollback
Bind Only if you need custom binding
  1. Run it as a second scheduler alongside the default (schedulerName in the pod spec). Never replace the default while learning — you will lock yourself out of your own cluster.
  2. Bin-packing versus spreading. The default spreads; GPUs usually want packing, so that whole nodes stay free for the next 8-GPU job. Implement a Score plugin that packs, then measure fragmentation: what fraction of free GPUs are unusable because they're scattered one-per-node? That number is the entire justification for the plugin.
  3. Topology awareness. Model NVLink domains and PCIe topology on your fake nodes. Two GPUs on the same NVLink island are worth far more to a training job than two across a PCIe root complex. Score for it. This is what "topology-aware placement" and "collective networking such as NCCL" mean in the posting.
  4. Utilization-aware placement. Feed project 1's live occupancy into Score — prefer nodes whose resident jobs are under-utilizing. Then confront the feedback loop: scheduling decisions change utilization, which changes future scheduling. Damp it, or watch it oscillate.
  5. Prove it. Replay a realistic job trace through both the default scheduler and yours. Report: GPU-hours stranded, fragmentation, mean queue wait, p95 time-to-start, gang deadlocks. A scheduler without a benchmark is an opinion.

Acceptance

  • Plugin running as a second scheduler, handling real pods
  • Measured improvement over default on a replayed trace, with the trace published
  • Topology-aware scoring with a written model of the hardware
  • An honest list of the cases where yours is worse than the default

Read: ../kubernetes/09-kube-scheduler-internals.md in full, ../kubernetes/34-custom-schedulers-and-scheduler-framework.md, ../kubernetes/10-kubelet-internals.md (device manager).


Sequence and effort

# Project Effort Depends on
0 Fake fleet + synthetic DCGM 1 week —
1 DCGM → Prometheus 1–2 weeks 0
2 Capacity & utilization dashboard 2 weeks 1, controller-tasks.md
3 Capacity planner 3–4 weeks 2, operator-tasks.md, admission-tasks.md
4 GPU job queue 3–4 weeks 3
5 Custom GPU scheduler 4–6 weeks 4, scheduling-framework-tasks.md

~4 months at 8–10h/week. If you only do two, do 1 and 3 — telemetry plus attribution is the Capacity Engineering role, and it's reachable without scheduler-framework depth. Projects 4 and 5 are the Kubernetes Platform role.

Publishing

Each project is a build-log: what you built, what the numbers did, what surprised you, where your design is worse than the incumbent. The last item is what makes the rest believable.

Project 5's benchmark is the single most credible artifact on this page — a measured comparison against the default scheduler on a published trace is evidence almost nobody outside a large infrastructure team can produce.

Label honestly: these run on a simulated fleet. "I built a GPU scheduler plugin and benchmarked it against the default on a 200-node simulated fleet" is accurate, impressive, and cannot be punctured. "I built GPU scheduling infrastructure" cannot survive a follow-up question.